fbpx

PS Article Published in Tri-State Seminar Proceedings

An article by Heather Jennings, PE, Director of Probiotic Solutions®, has been published in Tri-State Seminars Magazine, the proceedings of the 36th Annual Tri-State Seminar, held on August 9–12, 2021, in Las Vegas, Nev. Ms. Jennings was a featured presenter at the seminar, which provides training and certification classes to educate water professionals from Arizona, California, and Nevada.

In her presentation and the resulting published article, titled “Lagoons, Under the Surface,” Ms. Jennings discussed the results of an in-depth investigation of bioremediation and biological factors involved in reducing sludge at a municipal wastewater treatment facility lagoon system.

A one-year bioremediation plan was implemented for a municipal wastewater treatment facility with 2 primary lagoons in which sludge depths had reached 5–7 feet. The lagoons were at risk of upset and wastewater processing capacity was reduced. Sludge levels were reported for baseline and quarterly sludge judging, supplemented with ATP and DNA analyses of the microorganism biomass. The results of the ATP and DNA analyses pointed out the often-misunderstood fact that wastewater treatment facility lagoon sludge is not inert: it is the most biologically active layer of the water column and can be efficiently controlled and reduced through proper bioremediation interventions. Sludge depth was biologically reduced by an average of 45%. This represented 17,800 dry tons of sludge that did not need to be mechanically removed and hauled to a disposal location, a potential savings of over $6 million.

The complete article can be found on pp. 28–31 of the 2-2021 issue of Tri-State Seminars Magazine at https://www.kelmanonline.com/httpdocs/files/Tri-State-Seminar/issue2-2021/index.html.

Webinar Video: Lagoons Under the Surface

Webinar video highlights key findings—including $6M in savings—from a year-long bioremediation program for lagoon sludge reduction at a municipal wastewater treatment plant.

In this 31-minute video, Heather Jennings, PE, Director of Probiotic Solutions®, and Diego Lopez, Chief Plant Operator for the City of Lemoore, Calif., Wastewater Treatment Plant discuss highlights from the year-long study of a bioremediation program (using Bio Energizer®) for lagoon sludge reduction at a municipal wastewater treatment plant.

In the study, the operators of a municipal wastewater treatment facility with 4 lagoons had determined that their 2 primary lagoons—10-foot-deep, with 25-million-gallon holding capacity each—had reached sludge depths of 5–7 feet, putting the lagoons at risk of upset and seriously impacting the facility’s wastewater processing capacity.

A bioremediation plan was implemented that included the use of a biostimulant to support microbial reduction of the organic solids in the system. Sludge judging was performed for the 2 primary lagoons at baseline and at quarterly intervals over a one-year period to measure the impact of the bioremediation plan on sludge reduction.

The results of ATP and DNA analyses pointed out the often-misunderstood fact that wastewater treatment facility lagoon sludge is not inert: it is the most biologically active layer of the water column and can be efficiently controlled and reduced through proper bioremediation interventions

At the end of the one-year bioremediation plan, sludge depth for the 2 lagoons had been reduced by an average of 45%, with sludge depth at some sample points completely reduced to zero. This represented 17,800 dry tons of sludge that did not need to be mechanically removed and hauled to a disposal location, a potential savings to the treatment facility of over $6 million.

To read the full report in the Lagoons: Under the Surface white paper, CLICK HERE.

It’s ALIVE!

by Heather Jennings, PE

. . . the lagoon sludge layer, that is. I’ve seen many lagoons full of sludge, and the general attitude I find in the water industry is that the sludge layer is inert and really can only be mechanically dredged. To a certain point, that is correct: sand, soil, grit, plastics—basically inorganics—do need to be mechanically dredged. The organics, on the other hand, don’t, and they are easily removed with bioremediation. Continue Reading

Spring Is Coming and It’s Lagoon Time!

By Heather Jennings, PE

As winter loses its grip on us and we move toward spring, it’s finally time to start monitoring lagoons for seasonal turnover and stricter permit requirements. It’s also a great time to start bioremediation of your lagoon organic sludge!

With warmer weather it is easy to capitalize on those microorganisms that have been suppressed during the cooler months. A good example of this is a system we worked with in New Mexico that was dealing with irregular sludge build-up in their three lagoons. The system was modified to run in series relative to the influent rather than the short circuiting that took the first pond out of use. A 6-month test (later extended to 300 days) was developed in which Bio Energizer®, a bio stimulant, was administered to make nutrients more available to wastewater microorganisms.

Results: Pond 1 had a 12% sludge reduction, Pond 2 had a 36% reduction, and Pond 3 had a 24% reduction. The great thing is that no dredging expense was necessary, just daily application of Bio Energizer®.

To download/read the case study. click here for English or here for Spanish.

Use of Biostimulants for Upset Recovery in Paper Mill Wastewater Systems

By Heather Jennings, PE

Two specific Probiotic Solutions® liquid bioremediation products were used at a large-scale paper mill in China to address system upsets caused by hydraulic loading from new upstream processes.

The products involved are Bio Energizer® (BE)—a scientific formulation of organic acids, buffers, natural biological stimulants, micronutrients, and energy systems—and Micatrol® (MT), a specialized product that uses organic acid as a substrate to buffer wastewater microbial life. Both BE and MT are complexed with our proprietary Micro Carbon Technology® (MCT) to deliver readily bioavailable nutrients to microorganisms. [Read more…]

White Paper: Lagoons—Under the Surface

An In-Depth Investigation of Bioremediation and Biological Factors Involved in Reducing Sludge at a Municipal Wastewater Treatment Facility Lagoon System

Heather Jennings, PE, Sr. Project Engineer, Probiotic Solutions®

Abstract

In this study, the operators of a municipal wastewater treatment facility with 4 lagoons had determined that their 2 primary lagoons—10-foot-deep, with 25-million-gallon holding capacity each—had reached sludge depths of 5–7 feet, putting the lagoons at risk of upset and seriously impacting the facility’s wastewater processing capacity. Continue Reading

BIO ENERGIZER® Reduces Sludge 45% In One Year, Saves Municipal Plant $6 M In Dredging Costs

by Heather Jennings, PS

In this study, a one-year bioremediation plan featuring Bio Energizer® was implemented for a municipal wastewater treatment facility with 2 primary lagoons in which sludge depths had reached 5–7 feet. The lagoons were at risk of upset and wastewater processing capacity was reduced. 

Bio Energizer® was added via peristaltic pump to the lagoon inlets. Initially the dose applied was 7 ppm (7 gallons of product to 1,000,000 gallons of influent, assuming a typical Biochemical Oxygen Demand [BOD5] of 240 mg/L) and was eventually decreased 10 months later to 5 ppm. A maintenance dose of 3 ppm was established 2 months later.

Sludge levels were measured at baseline and quarterly. Sludge depth was biologically reduced by an average of 45%. This represented 17,810 dry tons of sludge that did not need to be mechanically removed and hauled to a disposal location, a potential savings of $6 million. When compared with product cost, and it was found that the facility product investment was 5.8% of the potential dredging costs.

To view the report, click here.

For more information about Bio Energizer®, click here.

Microplex® JS Jump Starts Utah Summer Camp WWTF

by Heather Jennings, PE

If I had to choose a favorite of our microbial products it would have to be our Microplex® JS product. It is a two-part formulation of a live synergistic blend of natural, Class I bacteria, specifically chosen for their ability to rapidly degrade solids, fats, lipids, proteins, detergents, hydrocarbons, and other compounds. It’s actually magical in the sense that we can start a new activated sludge plant with it or help one recover rapidly when biomass is lost. I can put it in and know it works. What’s even better is that it’s a live culture: mix two 50 ml vials in 55 gallons of water and within hours you have 55 gallons of microbial product ready to apply. Does it save the world? No, but if you’d like a break from some of the biomass issues you’ve been dealing with it can at least save you an ulcer or two. [Read more…]

Up to 85% Solids Destruction Achieved Using BIO ENERGIZER®

By Heather Jennings, PE

The wastewater treatment facility operators at a city in Missouri wanted better digester performance. They needed a better settling sludge and a higher volume of decants, as well as more room to waste sludge within their existing digesters. The options to dispose of the digested sludge were becoming more and more scarce.

After trialing 3 products, they found BIO ENERGIZER® reduced their solids the best. Significant improvement in settling as well as a significant reduction in the total solids occurred in their digesters. They have achieved up to 85% volatile solids destruction using BIO ENERGIZER®. Another benefit that the City has gained is increased decant volumes. The City has doubled the number of decants by using BIO ENERGIZER® compared with other products previously used. This all results in lower hauling and handling costs. All it takes is a peristaltic pump and the product to get you similar savings! [Read more…]

Anaerobic Digester Saves 42% In Sludge Hauling

by Heather Jennings, PE

The case summary described below is an example of how our Bio Energizer® product helped reduce overall solids handling and improved supernatant clarity. It really doesn’t take much Bio Energizer® to reduce solids within your system when the microbial community is stimulated or “kicked into gear” to do their job. Typically, in anaerobic digestion we dose between 1–2 gallons/MGD. This system had 250,000 gpd and, after an initial dose of 2 gallons, they added 7 oz/day of the product for 60 days in their primary digester. The results? The volume of each decant was double the normal volume, and they had half the solids loading with an average of 0.21% solids. Continuously using the product over two years yielded a net savings of $1,024/ month! [Read more…]

Translate »
>